Diaphragm Pump Trouble Shooting
| Problem | Cause | Solution |
|
Motor does not Start |
Electrical connections | Blown fuse,main switch and ground connection |
| Motor hot | Thermal Protect, wait until motor cool | |
| Incorrect Voltage | Use correct voltages (+/-10%) | |
| Pressure switch | Replace new one | |
|
Can not prime |
Restricted inlet | Check the strainer, hose,valves |
| Loose drive assembly | tighten the screw | |
| Air in the system | check all fixtures | |
| Incorrect Voltage | Use correct voltages (+/-10%) | |
|
Pump can not shut off |
Restricted inlet | Check the strainer,hose,valves |
| Loose drive assembly | Tighten the screw | |
| Air in the system | check all fixtures | |
| Incorrect Voltage | Use correct voltages(+/-10%) | |
| By-pass set higher than shut-off | Lower it down | |
| Noisy | Restricted inlet | Check the strainer,hose,valves |
| Air in the system | Check all fixtures | |
| Crude Mounting surface | Install on flat surface | |
| Loose drive assembly | Tighten the screw and the mounting feet | |
| Leaks | Loose drive assembly | Tighten the screw |
|
Switch or pump assembly rupture |
check the switch and pump head assembly and replace the kits, such as pressure gasket, diaphragm,check valve etc. |
|
| Low pressure/flow | Air in the system | Check all fixtures |
| Leak | Check all fixtures | |
| Incorrect Voltage | Use correct voltages (+/-10%) |